other equipment
бактерицидный облучатель рециркулятор
ультрафиолетовый облучатель
Duct Air Cleaner and Decontaminator Tion B
The duct air cleaning and disinfection device Tion B is a bactericidal device with the function of H11-H13 grade filtration and gas cleaning in supply and exhaust ventilation systems. The technology allows for simultaneous filtration of particles, inactivation (destruction) of all types of microorganisms, and air cleaning from odours and harmful gases. Tion B does not contain ultraviolet lamps. Meanwhile, it outperforms the efficiency of the bactericidal ultraviolet sections and fabric and paper HEPA filters, as well as sorption, electrostatic filters and their combinations.
Air filtration, decontamination and cleaning from harmful substances
Microbial inactivating efficiency has been confirmed for microorganisms of all pathogenicity groups, including tuberculosis, mold spores, etc.
Meets the standards for medical facilities.
No UV lamps: no more wiping, inspection or time logs.
The cost of replaceable elements is 5-20 times lower than that of HEPA filters and UV lamps.
бактерицидная установка, бактерицидный фильтр, бактерицидная секция, фильтр для очистки воздуха, очистка воздуха для вентиляции, бактерицидное обеззараживание, обеззараживание вентиляции.
Comparison of technologies
Tion B is an advantageous and convenient replacement of decontamination sections with UV lamps, HEPA filters and carbon filters which are often discrete in ventilation systems: the whole Tion B air cleaning and disinfection system is implemented in a single device.
Devices: | Only HEPA filters | HEPA filters combined with UV lamps | Charcoal filter | Duct Air Cleaner and Decontaminator Tion B |
Air filtration of HEPA H11-H13 grade from dust particles, allergens, viruses and bacteria. |
+ | + | – | + |
Inactivation (destruction) of indicative microorganisms (staphylococcus) with the efficiency above 95%. |
– | + | – | + |
Inactivation (destruction) of hard-to-destroy microorganisms (mold spores, tuberculosis, etc.) with the efficiency above 95%. |
– | – | – | + |
Cleaning from harmful substances and odours up to the MPC level. |
– | – | + | + |
Tion B not only cleans and disinfects the air, but also cleans it from dust, allergens, harmful substances, and odours.
Similar high decontamination efficiency for all types of microorganisms, including those UV-resistant: mold, tuberculosis microbacteria, etc.
A high grade of filtration prevents dead microorganisms from penetrating into the premise.
Unlike UV lamps located in ventilation ducts, no time logs are required for Tion B.
No lamps means no more wiping, inspection or special disposal.
It does not emit harmful substances and does not form hazardous irradiation.
Tion B is absolutely safe for 24-hour operation in presence of people.
Differential pressure on Tion filters is several times lower than that on fabric HEPA filters.
Replaceable elements are cheaper than UV lamps.
Power consumption is several times lower than that of UV recirculators.
Tion B working principle
Tion B cleans and disinfects the air coming into the device from the forced ventilation system or recirculation system of the building, filtering everything from mechanical to chemical impurities, inactivating (destroying) all types of microorganisms (including tuberculosis microbacteria, mold spores) and cleaning from harmful gases.
The pre-filter (1) entraps coarse dust and prevents coarse contaminant particles from penetrating into the device.
While passing through the electrostatic unit (2), the mechanical contaminants and bioaerosols gain an electric charge and are effectively captured on a bulk HEPA filter (3).
The electrostatic unit uses ozone produced from oxygen in bactericide concentrations for inactivation (destruction) of viruses, bacteria and mold spores. Due to inactivation, the bulk HEPA filter is permanently sterile during operation, including filter replacement (it does not require special methods for disposal of the used filters). Therefore, complete microbiological safety of the filtration system is ensured.
Ozone totally decomposes to oxygen while passing through the adsorption-catalytic filter (4), simultaneously speeding up the reactions of destruction of molecular chemical compounds. The adsorption-catalytic filter is designed for filtration of harmful substances in gaseous state, as well as the odours. Ozone concentration at the device outlet does not exceed MPC (daily average) during the whole lifetime. Therefore, the device can be operated 24 hours a day in the presence of people. When used, the device does not change the microclimatic parameters (temperature, moisture) and the ion composition of the air.
The device is controlled and managed with the help of an automation unit (5). An indicator panel is provided for the suspended models.
Supply air cleaning
Tion B is installed in the supply ventilation duct of medical institutions (A and B grade premises) for sterile and cleaned air supply to meet the regulatory requirements on the content of particles and microorganisms in the air. It is installed downstream from the air supply unit.
Exhaust air cleaning
Tion B is installed in the exhaust ventilation duct of infectious disease wards, sections or bio laboratories when the safety of people and the air medium outside the building is to be warranted. It is installed upstream from the air exhaust unit.
Tion B operation
CHOOSING DUCT AIR FILTER AND DECONTAMINATOR TION B
The integrated air cleaning and disinfecting device Tion B is chosen according to the ventilation system performance and the required cleanroom class of the premise. Tion B is installed in the ventilation duct downstream or upstream from the ventilating unit.
OPERATION MODE “SWITCH ON AND FORGET”
No lamp wiping, inspection or time logs are required. Inactivation of microorganisms on the filters ensures absolute sterility of replaceable elements of Tion B and abolishes the need for special disposal measures.
Tion В150T
For all grades of purity
Type: floor/wall mounted
Rate: 300-900m3/h
Disinfection: 99.9%
Inactivation: 99%
Filtration G4+H13(99,95%)
Gas cleaning up to MPC norms
Differential pressure: 70-100Pa
Warranty: 1 year
Tion В1000T
For all grades of purity
Type: floor/wall mounted
Rate: 2000-3000m3/h
Disinfection: 99.9%
Inactivation: 99%
Filtration G4+H13(99,95%)
Gas cleaning up to MPC norms
Differential pressure: 460-580Pa
Warranty: 1 year
Tion В150
For all grades of purity
Type: floor mounted
Rate: 300-2400m3/h
Disinfection: 99.9%
Inactivation: 99%
Filtration G4+H11(99,95%)
Gas cleaning up to MPC norms
Differential pressure: 70-100Pa
Warranty: 1 year
Tion В1000
For all grades of purity
Type: floor mounted
Rate: 2000-27500m3/h
Disinfection: 99.9%
Inactivation: 99%
Filtration G4+H11(99,95%)
Gas cleaning up to MPC norms
Differential pressure: 235-300Pa
Warranty: 1 year
х-О-S Model
The device model is chosen according to the selection table in compliance with ventilation capacity. Floor-mounted devices of equal capacity can differ in section configuration and have various sizes (see the selection table).
X – ventilation system performance.
O – the device needs to be installed outside the building, which assumes installation of a cover protecting the device from rain and snow.
S – special configuration with individual properties is required.
For example, Tion В150 Т x450 can be suspended and/or floor-mounted in the ventilation system with the capacity up to 450 m3/h. Floor-mounted device Tion В1000 x5000 -O.M can be used, as the selection table suggests, for a ventilation system with the capacity 4800 m3/h and for possible outside installation.
Ventilation capacity, m3/h | Tion B model | Overall dimensions, mm | Adapter flange dimensions, mm | Weight, kg | Power, W | |||
L | W | H | Wconnect | Hconnect | ||||
Floor/wall mounted duct air cleaner Tion B150T |
||||||||
300 | Tion B150 Т x300 | 900 | 635 | 290 | 481 | 246 | 32 | 10 |
450 | Tion B150 Т x450 | 900 | 860 | 290 | 706 | 246 | 41 | 10 |
600 | Tion B150 Т x600 | 900 | 1085 | 290 | 931 | 246 | 50 | 15 |
750 | Tion B150 Т x750 | 900 | 1310 | 290 | 1156 | 246 | 59 | 15 |
900 | Tion B150 Т x900 | 900 | 1535 | 290 | 1381 | 246 | 68 | 20 |
Floor/wall mounted duct air cleaner Tion B1000T |
||||||||
2000 | Tion B1000 Т x2000 | 1400 | 820 | 350 | 656 | 306 | 55 | 35 |
3000 | Tion B1000 Т x3000 | 1400 | 1120 | 350 | 956 | 306 | 72 | 50 |
Floor-mounted duct air cleaner Tion B150 |
||||||||
300 | Tion B150 x300 H1V2 | 900 | 330 | 635 | 246 | 481 | 30 | 10 |
450 | Tion B150 x450 H1V3 | 900 | 330 | 860 | 246 | 706 | 38 | 10 |
450 | Tion B150 x450 H2V2 | 900 | 580 | 635 | 496 | 481 | 40 | 10 |
600 | Tion B150 x600 H1V4 | 900 | 330 | 1085 | 246 | 931 | 47 | 15 |
600 | Tion B150 x600 H2V2 | 900 | 580 | 635 | 496 | 481 | 43 | 15 |
750 | Tion B150 x750 H2V3 | 900 | 580 | 860 | 496 | 706 | 53 | 15 |
750 | Tion B150 x750 H3V2 | 900 | 830 | 635 | 746 | 481 | 53 | 15 |
900 | Tion B150 x900 H2V3 | 900 | 580 | 860 | 496 | 706 | 57 | 20 |
900 | Tion B150 x900 H3V2 | 900 | 830 | 635 | 746 | 481 | 57 | 20 |
1050 | Tion B150 x1050 H2V4 | 900 | 580 | 1085 | 496 | 931 | 67 | 20 |
1050 | Tion B150 x1050 H3V3 | 900 | 830 | 860 | 746 | 706 | 68 | 20 |
1050 | Tion B150 x1050 H4V2 | 900 | 1080 | 635 | 996 | 481 | 67 | 20 |
1200 | Tion B150 x1200 H2V4 | 900 | 580 | 1095 | 496 | 931 | 71 | 25 |
1200 | Tion B150 x1200 H3V3 | 900 | 830 | 870 | 746 | 706 | 72 | 25 |
1200 | Tion B150 x1200 H4V2 | 900 | 1080 | 645 | 996 | 481 | 71 | 25 |
1350 | Tion B150 x1350 H2V5 | 900 | 580 | 1320 | 496 | 1156 | 84 | 25 |
1350 | Tion B150 x1350 H3V3 | 900 | 830 | 870 | 746 | 706 | 79 | 25 |
1350 | Tion B150 x1350 H5V2 | 900 | 1330 | 645 | 1246 | 481 | 85 | 25 |
1500 | Tion B150 x1500 H2V5 | 900 | 580 | 1320 | 496 | 1156 | 88 | 25 |
1500 | Tion B150 x1500 H3V4 | 900 | 830 | 1095 | 746 | 931 | 90 | 25 |
1500 | Tion B150 x1500 H4V3 | 900 | 1080 | 870 | 996 | 706 | 91 | 25 |
1500 | Tion B150 x1500 H5V2 | 900 | 1330 | 645 | 1246 | 481 | 89 | 25 |
1650 | Tion B150 x1650 H3V4 | 900 | 830 | 1095 | 746 | 931 | 95 | 30 |
1650 | Tion B150 x1650 H4V3 | 900 | 1080 | 870 | 996 | 706 | 95 | 30 |
1800 | Tion B150 x1800 H3V4 | 900 | 830 | 1095 | 746 | 931 | 98 | 30 |
1800 | Tion B150 x1800 H4V3 | 900 | 1080 | 870 | 996 | 706 | 99 | 30 |
1950 | Tion B150 x1950 H3V5 | 900 | 830 | 1320 | 746 | 1156 | 110 | 35 |
1950 | Tion B150 x1950 H4V4 | 900 | 1080 | 1095 | 996 | 931 | 112 | 35 |
1950 | Tion B150 x1950 H5V3 | 900 | 1330 | 870 | 1246 | 706 | 111 | 35 |
2100 | Tion B150 x2100 H3V5 | 900 | 830 | 1320 | 746 | 1156 | 114 | 35 |
2100 | Tion B150 x2100 H4V4 | 900 | 1080 | 1095 | 996 | 931 | 115 | 35 |
2100 | Tion B150 x2100 H5V3 | 900 | 1330 | 870 | 1246 | 706 | 114 | 35 |
2250 | Tion B150 x2250 H3V5 | 900 | 830 | 1320 | 746 | 1156 | 118 | 40 |
2250 | Tion B150 x2250 H4V4 | 900 | 1080 | 1095 | 996 | 931 | 119 | 40 |
2250 | Tion B150 x2250 H5V3 | 900 | 1330 | 870 | 1246 | 706 | 118 | 40 |
2400 | Tion B150 x2400 H4V4 | 900 | 1080 | 1095 | 996 | 931 | 123 | 40 |
Floor-mounted duct air cleaner Tion B1000 |
||||||||
2000 | Tion B1000 x2000 H1V2 | 1400 | 390 | 820 | 306 | 656 | 59 | 35 |
3000 | Tion B1000 x3000 H1V3 | 1500 | 440 | 1170 | 316 | 966 | 112 | 50 |
3000 | Tion B1000 x3000 H2V2 | 1500 | 784 | 870 | 660 | 666 | 118 | 50 |
4000 | Tion B1000 x4000 H1V4 | 1500 | 440 | 1470 | 316 | 1266 | 138 | 70 |
4000 | Tion B1000 x4000 H2V2 | 1500 | 784 | 870 | 660 | 666 | 129 | 70 |
5000 | Tion B1000 x5000 H2V3 | 1500 | 784 | 1170 | 660 | 966 | 158 | 85 |
5000 | Tion B1000 x5000 H3V2 | 1500 | 1128 | 870 | 1004 | 666 | 160 | 85 |
6000 | Tion B1000 x6000 H2V3 | 1500 | 784 | 1170 | 660 | 966 | 168 | 100 |
6000 | Tion B1000 x6000 H3V2 | 1500 | 1128 | 870 | 1004 | 666 | 170 | 100 |
7000 | Tion B1000 x 7000 H2V4 | 1500 | 784 | 1470 | 660 | 1266 | 198 | 120 |
7000 | Tion B1000 x7000 H3V3 | 1500 | 1128 | 1170 | 1004 | 966 | 203 | 120 |
7000 | Tion B1000 x7000 H4V2 | 1500 | 1472 | 870 | 1348 | 666 | 202 | 120 |
8000 | Tion B1000 x8000 H2V4 | 1500 | 784 | 1470 | 660 | 1266 | 208 | 135 |
8000 | Tion B1000 x8000 H3V3 | 1500 | 1128 | 1170 | 1004 | 966 | 213 | 135 |
8000 | Tion B1000 x8000 H4V2 | 1500 | 1472 | 870 | 1348 | 666 | 213 | 135 |
9000 | Tion B1000 x9000 H2V5 | 1500 | 784 | 1770 | 660 | 1566 | 238 | 150 |
9000 | Tion B1000 x9000 H3V3 | 1500 | 1128 | 1170 | 1004 | 966 | 223 | 150 |
9000 | Tion B1000 x9000 H5V2 | 1500 | 1816 | 870 | 1692 | 666 | 245 | 150 |
10000 | Tion B1000 x10000 H2V5 | 1500 | 784 | 1770 | 660 | 1566 | 248 | 170 |
10000 | Tion B1000 x10000 H3V4 | 1500 | 1128 | 1470 | 1004 | 1266 | 257 | 170 |
10000 | Tion B1000 x10000 H4V3 | 1500 | 1472 | 1170 | 1348 | 966 | 259 | 170 |
10000 | Tion B1000 x10000 H5V2 | 1500 | 1816 | 870 | 1692 | 666 | 255 | 170 |
11000 | Tion B1000 x11000 H3V4 | 1500 | 1128 | 1470 | 1004 | 1266 | 267 | 185 |
11000 | Tion B1000 x11000 H4V3 | 1500 | 1472 | 1170 | 1348 | 966 | 270 | 185 |
12000 | Tion B1000 x12000 H3V4 | 1500 | 1128 | 1470 | 1004 | 1266 | 277 | 200 |
12000 | Tion B1000 x12000 H4V3 | 1500 | 1472 | 1170 | 1348 | 966 | 280 | 200 |
13000 | Tion B1000 x13000 H3V5 | 1500 | 1128 | 1770 | 1004 | 1566 | 311 | 215 |
13000 | Tion B1000 x13000 H4V4 | 1500 | 1472 | 1470 | 1348 | 1266 | 317 | 215 |
13000 | Tion B1000 x13000 H5V3 | 1500 | 1816 | 1170 | 1692 | 966 | 316 | 215 |
14000 | Tion B1000 x14000 H3V5 | 1500 | 1128 | 1770 | 1004 | 1566 | 321 | 235 |
14000 | Tion B1000 x14000 H4V4 | 1500 | 1472 | 1470 | 1348 | 1266 | 327 | 235 |
14000 | Tion B1000 x14000 H5V3 | 1500 | 1816 | 1170 | 1692 | 966 | 326 | 235 |
15000 | Tion B1000 x15000 H3V5 | 1500 | 1128 | 1770 | 1004 | 1566 | 332 | 250 |
15000 | Tion B1000 x15000 H4V4 | 1500 | 1472 | 1470 | 1348 | 1266 | 338 | 250 |
15000 | Tion B1000 x15000 H5V3 | 1500 | 1816 | 1170 | 1692 | 966 | 336 | 250 |
16000 | Tion B1000 x 16000 H4V4 | 1500 | 1472 | 1470 | 1348 | 1266 | 348 | 265 |
27500 | on demand | |||||||